Plug your Touch Probe into the Touch Probe Mount Connector.

Before using the probe, it is good practice to test the clip against the Probe to ensure correct installation.

Attach the Touch Probe Clip to an Endmill which is not in the Router like image 2.

Go to Dashboard > Under Touch Probe Control Panel > Press Z under Probe Individual Axis. Confirm the on screen prompt. Wait for the Machine to move the Z Axis Down and then engage the Endmill with the probe. Once engaged the Z Axis should stop moving.

If it doesn't stop please use the Emergency Stop.

If the Z-Axis changes direction once the endmill has engaged then the Touch Probe is operating correctly.

If the Probe does not work please check your wiring and the Touch Probe settings.