I am getting an error message “motor phase B may be disconnected” this refers to the right hand stepper motor (looking from the fron of the machine) I have tried cleaning to terminals but no joy any ideas

Thanks

Tom

Answered! View the answer I have this problem too

Is this a good question?

Score 0

Comments:

Hi Robert

Yes there was burning on the connection I have changed the wire and everything seems to be ok

Thanks

Tom

by

hi guys, i am having the same issue is this as simple as changing the wire and the terminals

by

Hi Pete, if you contact us here: https://ooznest.co.uk/help/ we should be able to help you further. Best Regards Ryan Lock

by

Add a comment

1 Answer

Chosen Solution
User avatar

Hi Thomas,

Thanks for your question. Can you check for any burnt marks on the white connector on the wire side?

Robert

Was this answer helpful?

Score 1
Add a comment