Skip to main content
User avatar

Firmware update in access point mode

Hi, my workbee is in access point. Is this a problem for firmware 1.07 to 3.3? Also is the update done over wifi or do I need to connect via usb?

Answered! View the answer I have this problem too

Is this a good question?

Score 0
Add a comment

1 Answer

Chosen Solution
User avatar

Hi Tezza,

Thanks for your question.

The update can still be done.

On Step 10, like Ethernet users, edit config-network.g

And put a ; in front of M552 S1

And remove the ; in front of M552 S2.

Then it should all work correctly on Access Point.

Robert

Was this answer helpful?

Score 0

Comments:

Thanks, but do I do all the update over wifi or do you connect to duet via usb to carry out update?

by

@terryjan In this guide: How To Update WorkBee Firmware V1.0.7 > V3.3.0-1.2

You do everything over Wifi. You do not need to connect via USB, unless something goes wrong. But contact us first :)

by

Add a comment

Add your answer

Author avatar Tezza will be eternally grateful.
View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 1

All Time: 61