Hi Nigel,
Thanks for linking the guide about Peter. It is slightly out of date. Here would be the latest instructions for the Z1+
To put your Controller into Access Point Mode please complete this guide to get connected via USB: ++https://learn.ooznest.co.uk/Guide/1.+C...
Once in YAT send the following commands:
M552 S0
Wait 10 seconds
M552 S2
If you now go to your computers WiFi list. There should be one called 'WorkBee'
Connect to it using the password: 00000000
Then in the Web Browser go to the IP Address: 10.10.10.10
It should connect to WorkBee Control
To make this permanent. Inside WorkBee Control go to File Management > System Settings > Edit config-network.g
Change the following section:
; Configure Connection - ENABLE ONLY ONE OF THE BELOW THREE
M552 S1 ; Enable Wifi Network
;M552 S2 ; Enable Access Point Mode
;M552 S1 P192.168.251.2 ; Enable Ethernet - Change IP Address to suit
To:
; Configure Connection - ENABLE ONLY ONE OF THE BELOW THREE
;M552 S1 ; Enable Wifi Network
M552 S2 ; Enable Access Point Mode
;M552 S1 P192.168.251.2 ; Enable Ethernet - Change IP Address to suit
Once changed your board should restart and now permanently be in Access Point Mode.