Hi Anthony,
The default password is 00000000
If that does not work and you need to set it up again, here are the instructions:
Can you connect via USB following this guide:
- 1. Connecting your Controller via USB - Windows
(Mac Version: 1. Connecting your Controller via USB - MacOS)
Once connected, send the following commands in YAT:
- M552 S0
- M589 S"WorkBee" P"00000000" I10.10.10.10
(If you get an error like the network already exists that is ok, proceed to the next step)
- M552 S2
- On your computer, look at the available Wifi networks
- Connect to the one called 'WorkBee' and use password: 00000000
- In your Web Browser go to the IP Address 10.10.10.10
- To make this change permanent go to Files > System
- Open config-network.g
- Change the following section:
; Configure Connection - ENABLE ONLY ONE OF THE BELOW THREE
M552 S1 ; Enable Wifi Network
;M552 S2 ; Enable Access Point Mode
;M552 S1 P192.168.251.2 ; Enable Ethernet - Change IP Address to suit
To:
; Configure Connection - ENABLE ONLY ONE OF THE BELOW THREE
;M552 S1 ; Enable Wifi Network
M552 S2 ; Enable Access Point Mode
;M552 S1 P192.168.251.2 ; Enable Ethernet - Change IP Address to suit
- Save and restart
- It should now auto-boot into Access Point Mode
- Remove the USB Cable and switch to Mains Power